TM 9-2350-261-20-2 6.7.8.9.W A R N I N GAir pressure in excess of 30psi (207 kpa) can injure per-sonnel. Do not direct pres-surized air at yourself orothers. Always wear gog-gles..10.11.12.Attach radiator cleaning tool to available airsupply.Rinse radiator with clear water.Clean sand, oil, and debris from radiator.Remove siphon hose from detergent solution.AIR SUPPLY LINELIQUID SUPPLY LINERemove excess water with available airsupply.Uncover exposed engine openings.Secure radiator access door (1) to radiatoropening with two fasteners (2).13. Secure radiator access panel (3) to powerplant compartment bulkhead with twoclamps (4) and thumbscrews (5).FOLLOW-THROUGH STEPS 1. Install hull bottom access cover (page 24-32).4.2. Install driver’s power plant access panel(see your -10).5.3. Install power plant rear access panel(see your -10).Close power plant front access door(see your -10).Raise trim vane (see your -10).END OF TASK8-8