TM 9-2350-261-20-2REPLACE CIRCUIT 6 LEAD (ALL EXCEPT M577A2 AND M1068) DESCRIPTIONThis task covers:Remove (page 13-13).Clean, Inspect, and Repair (page 13-14).Install (page 13-14).INITIAL SETUP Tools:General Mechanics Tool Kit (Item 30, App D)Battery Terminal Cleaner (Item 13, App D)Multimeter (Item 43, App D)Battery Terminal Puller (Item 46, App D)Materials/PartsGrommet (2)Personnel Required: Unit MechanicReferences:See your -10Equipment Conditions: Engine stopped/shutdown (See your -10) Carrier blocked (see your -10)Ramp lowered (see your -10)Battery ground lead disconnected (page 13-2)Battery box cover removed (page 13-3)REMOVEWARNINGGas from batteries can ex-plode. Ventilate compart-ment before you disconnector connect battery cables.Battery acid can burn orblind you. Do not get acidon your skin or eyes. ALWAYS disconnectground lead (circuit 7) first and connect itlast.1. Remove nut (1), circuit 6 lead (2), and screw(3) from terminal lug (4).2. Remove lead (2) and grommet (5) from bat-tery box (6). Discard grommet.3. On M113A2, M741A1, and M901A1 carriers,remove five clips (7) from cradles (8). Removelead (2) from cradles.4. Remove five screws (9) and cradles (8) fromhull weldnuts.GO TO NEXT PAGE13-13CHANGE 3