TM 9-2350-261-20-2R E P L A C E C I R C U I T B R E A K ERINITIAL SETUPTOOIS:General Mechanics ToolMaterials/Parts:Self-locking nut (2)Personnel Required:Unit MechanicReferencesKit (Item 30, App D)See your -10Equipment Conditions:Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Battery ground lead disconnected (page 13-2)Instrument panel removed (page 11-2)REMOVE1. Disconnect circuit 10 lead (1) and circuit 27lead (2) from circuit breaker (3).2. Remove two locknuts (4), screws (5), andcuit breaker (3) from rear of instrumentpanel. Discard locknuts.INSTALL3.4.Place circuit breaker (3) on rear of instru-cir-ment panel. Secure with two screws (5) andnew locknuts (4).Connect circuit 27 lead (2) and circuit 10 lead(1) to circuit breaker (3).FOLLOW-THROUGH STEPS1. Install instrument panel (page 11-2).3. Turn MASTER SWITCH ON, light shouldcome on for proper installation of circuit2. Connect battery ground lead (page 13-2).breaker. (see your -10).4. Turn MASTER SWITCH OFF (see your -10).END OF TASK11-4