TM 9-2350-261-20-2
R E P L A C E C I R C U I T B R E A K ER
INITIAL SETUP
TOOIS:
General Mechanics Tool
Materials/Parts:
Self-locking nut (2)
Personnel Required:
Unit Mechanic
References
Kit (Item 30, App D)
See your -10
Equipment Conditions:
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (page 13-2)
Instrument panel removed (page 11-2)
REMOVE
1. Disconnect circuit 10 lead (1) and circuit 27
lead (2) from circuit breaker (3).
2. Remove two locknuts (4), screws (5), and
cuit breaker (3) from rear of instrument
panel. Discard locknuts.
INSTALL
3.
4.
Place circuit breaker (3) on rear of instru-
cir-
ment panel. Secure with two screws (5) and
new locknuts (4).
Connect circuit 27 lead (2) and circuit 10 lead
(1) to circuit breaker (3).
FOLLOW-THROUGH STEPS
1. Install instrument panel (page 11-2).
3. Turn MASTER SWITCH ON, light should
come on for proper installation of circuit
2. Connect battery ground lead (page 13-2).
breaker. (see your -10).
4. Turn MASTER SWITCH OFF (see your -10).
END OF TASK
11-4