TM 9-2350-261-20-2
CLEAN, INSPECT, AND REPAIR
6. Check terminal strip. Replace circuit breaker
that has cracked terminal strip.
INSTALL
NOTE
When
i n s t a l l i n g a
new
genera-
tor-regulator circuit breaker, discard two
of the four lockwashers supplied with
circuit breaker.
7. Place circuit breaker (1) in distribution
box (2). Secure with two screws (3) and
new locknuts (4).
8. Place circuit 3 lead (5) and terminal
strip (6) on circuit breaker (1). Secure with
two new Iockwashers (7) and two
screws (8).
9. Align teminal strip (6) with hole in
distribution box (2). Secure with screw (9),
two washers (10), and new locknut (11 ).
10. Place distribution box (2) on hull
mounts (12). Secure with five new
Iockwashers (13) and screws (14).
11. Place master switch panel (15) on
distribution box (2). Secure with eight
screws (16), washers (17), and new
locknuts (18).
FOLLOW-THROUGH STEPS
1. Connect battery ground lead (page 13-2).
3. Stop engine (see your -10).
2. Start engine and check the
generator-regulator circuit breaker. The
BATT-GEN gage should be in green area
(see your -10).
END OF TASK
9-43