TM 9-2350-261-20-1
REPLACE FUEL RETURN HOSES, TUBES, AND FITTINGS
(M577A2 AND M1068 ONLY)
DESCRIPTION
This task covers: Remove (page 6-66).
Install (page 6-68).
INITIAL SETUP
Tools:
General Mechanics Tool Kit (Item 30, App D)
Materials/Parts:
Sealing compound (Item 46, App
Wiping rag (Item 61, App C)
C)
Lockwasher (8)
Self-locking nut
Personnel Required:
Unit Mechanic
References:
see your -10
REMOVE
WARNING
Fuel flowing over a metal
surface
causes
static
electricity. This will cause a
spark unless the surface is
grounded.
NOTE
Use wiping rag to wipe up any spilled fuel.
1. Disconnect return tube (1) from elbow (2).
2. Remove elbow (2) from filler neck (3).
3. Disconnect return tube (1) from nipple (4) or
tee (4.1) (M1068).
4. Remove four screws (5), lockwashers (6),
clamps (7), and return tube (1) from four
weldnuts (8). Discard lockwashers.
5. Deleted.
Equipment Conditions:
Engine stopped/shutdown and ramp lowered
(see your -10)
Battery ground lead disconnected (page 13-2)
Electronic equipment heater removed
(page 31-16)
Generator removed (page 9-81 and 9-34)
Personnel heater removed (page 29-51)
Muffler removed (page 7-20)
Power plant rear access panel removed
(page 24-29)
Map board removed (see your -10)
Carrier blocked (see your -10)
6-66
Change 4