TM 9-2350-261-20-17. Pusha. Iftob. IfVTM circuit breaker to ON.display reads (8888) and (- -- -), gostep 8.display is not blank, but does not read(8888) and (- - - -), write up DA form2404 on faulty VTM display. Reportproblem to supervisor.c. If display is blank, go to VTM blankdisplay diagnostic troubleshooting(see TM 9-4910-571-12&P).8. Perform VTM confidence check(see TM 9-4910-571-12&P). If VTMconfidence check does not pass, go toSTE/ICE confidence test fault isolation(see TM 9-4910-571-12&P).9. Select test 60, then press and release TESTbutton.10.11.12.Enter earner VID (03) into VTM, thenpress and release TEST button.Select test 61, then press and release TESTbutton. If earner VID (03) does not appearon VTM display,(see-TM 9-4910-571-12&P). Return to troubleshooting.13.14.15.16.Pull VTM circuit breaker to OFF.Remove power cable W5 from batteries andVTM. Use electrical connector pliers.Install battery cover. See CHECK CARRIERBATTERIES in your -10.Stow VTM and power cable W5 in transitcase.END OF TASK3-276Change 1R E M O V E