TM 9-2350-261-20-11. Move red clip of test probe cable W2 to ground terminal1. Clean, inspect, and repairof starter.cables as needed.2. Crank engine and read displayed voltage.2. Verify no faults found.3. Is voltage drop less than 18 volts?I1. Replace starter (page 10-2).2. Verify no faults found.Iv1. Move red clip of test probe cable W2 to positive terminalof starter solenoid.2. Crank engine and read displayed voltage.3. Is solenoid voltage above 18 volts?YES1. If GO message occurred during starter circuit resis-tance test, check switches and wiring to solenoid.NOTEVoltage drop across a connection shouldbe less than 0.1 volt and a voltage dropacross a cable should be less than 0.2volts. Check voltage drop across solenoidand all cables/connections in positiveside if starter circuit.2. Set test select switches to 89.3. Connect clip leads of test probe W2 across part to bemeasured.4. Press and release test button.5. Engage starter.6. Repair part if voltage drop is high.7. If ’switches and wiring to solenoid are ok, replace sole-noid and starter (page 10-2).8. Verify no faults found.3-262Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business