TM 9-2350-261-20-1
1. Move red clip of test probe cable W2 to ground terminal
1. Clean, inspect, and repair
of starter.
cables as needed.
2. Crank engine and read displayed voltage.
2. Verify no faults found.
3. Is voltage drop less than 18 volts?
I
1. Replace starter (page 10-2).
2. Verify no faults found.
I
v
1. Move red clip of test probe cable W2 to positive terminal
of starter solenoid.
2. Crank engine and read displayed voltage.
3. Is solenoid voltage above 18 volts?
YES
1. If GO message occurred during starter circuit resis-
tance test, check switches and wiring to solenoid.
NOTE
Voltage drop across a connection should
be less than 0.1 volt and a voltage drop
across a cable should be less than 0.2
volts. Check voltage drop across solenoid
and all cables/connections in positive
side if starter circuit.
2. Set test select switches to 89.
3. Connect clip leads of test probe W2 across part to be
measured.
4. Press and release test button.
5. Engage starter.
6. Repair part if voltage drop is high.
7. If switches and wiring to solenoid are ok, replace sole-
noid and starter (page 10-2).
8. Verify no faults found.
3-262
Change 1