TM 9-2350-261-20-1
1. Error message E013 displayed earlier indicates short
circuit, frozen starter, or tight engine.
2. Check wiring to starter for short circuits.
3. If wiring is ok, engine maybe tight.
4. Notify direct support maintenance.
5. Verify no faults found.
1. Is resistance high?
NO
1. Repair short circuit in
starter circuit.
YES
2. Verify no faults found.
1. Attempt to start engine while listening for clicking of
NO
1. Check switches, wiring,
starter solenoid.
relays, and circuit breakers
2. Does starter solenoid click?
to starter solenoid.
1. Connect test probe cable W2P1 to J4 on VTM.
2. Connect red and black clips together.
3. Set test select switches to 89.
4. Press and hold test until CAL appears on display.
5. Is offset value within limits of -6.8 to +6.8?
YES
1. Connect black clip of test probe cable W2 to the negative
battery terminal.
2. Connect red clip of test probe cable W2 to the positive
terminal of starter.
3. Press and release test button.
4. Crank engine and read displayed voltage.
5. Is starter voltage above 17 volts?
GO TO NEXT PAGE
I 2. Verify no faults found.
NO
1. Go to offset fault isolation
(TM 94910-571-12&P).
I 2. Verify no faults found.
NEXT PAGE
Change 1
3-261