TM 9-2350-261-20-1S T E / I C E - R S T A R T E R C I R C U I T T R O U B L E S H O O T I N GINITIAL SETUPTools:General Mechanic’s Tool Kit (Item 30, App D)STE/ICE-R Test Set (Item 71.1, App D)Personnel Required:Unit MechanicReferences:See your –10TM 9-4910-571-12&P TM 9-6140-200-14 References (cont):Engine cranks slowly (page 3-25)Equipment Conditions:Engine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant access door open (see your -10)All electrical power off (see your -10)STE/ICE-R hooked up for tests 72 thru 75(page 3-281)STE/ICE-R hooked up for power (page 3-275)1. Make sure all electrical accessories are off.2. Set test select switches to 74.3. Press and hold test button until CAL appears ondisplay.4. Release test button, wait for offset value to appear ondisplay.5. Is offset value within-225 to +225?YES1. Install current probe on positive battery cable.2. Shut off fuel.3. Press and release test button.N O TEWhile cranking engine with bad ordischarged batteries, it is possible forVTM to lose power and come on againafter cranking has stopped. If thisoccurs, clean battery posts and clamps.If they are loose or corroded, correctthem and repeat test.4. When GO appears, crank engine until OFF or ERRORmessage is displayed (normally 5 seconds).5. Is a number displayed?1G O T O N E X T P A G E1. Go to offset fault isolation(TM9-4910-571-12&P).II 2. Verify no faults found.IChange 13-259