TM 9-2350-261-20-1OUTPUT CURRENT 1. Set test select switches to 01.2. Press and release test button.3. When PASS appears, set test select switches to 03.4. Press and release test button.5. When PASS appears, set test select switches to 90.6. Press and release test button.7. Turn on lights and accessories.8. Set engine speed to 1000 to 1200 rpm.9. Is output current below 70 amps?YES1. Stop engine (see your-10).2. Turnoff lights and accessories.3. Adjust generator drive belts (page 9-44).4. Are drive belts ok?Y ES1. Check operation of generator field switch (page 9-44).2. Was generator field switch repaired?I 1. Verify no faults found.1. Go to battery/generatorindicator malfunctions(page 3-143).2. Verify no faults found.1. Replace generator drive belts(page 9-29).2. Verify no faults found.1.2.Check charging systemcables for loose or corrodedconnections.Verify no faults found.Change 13-257