1.
2.
3.
4.
Set AC RIGHT OUTLETS switches (1) to OFF and
remove ALL power from SICPS system
(see your -10 and TM 11-7010-256-12&P).
Remove cable W8 plug P1 (2) from Curbside AC Power
Extension Box jack J1 (3).
Measure resistance between pins of plugs P1 (2) and
P11 (4) on cable W8 as follows:
P1 pin A to P11 pin A
P1 pin B to P11 pin B
P1 pin C to P11 pin C
P1 pin D to P11 pin D
P1 pin E to P11 pin E
Does multimeter read 0 ohms for each set of pins?
1. Replace Curbside AC Power Extension Box A7
(page 40.1-12).
2. Verify no faults found.
TM 9-2350-261-20-1
1. Replace cable W8
(page 40.1-68).
I
2. Verify no faults found.
Change 3
3-226.29