TM 9-2350-287-20-1
7-74. DCA TO DRIVERS BULKHEAD STE/lCE WIRING HARNESS (12329996) REPLACEMENT
(continued).
b.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
INSTALLATION
Connect plug (33) to air cleaner pressure transducer
(32).
Connect plug (26) to engine pulse tachometer (25).
Install wiring harness 12329996 (29) on air cleaner
assembly (31) with clamp (30), washer (28), and new
self-locking nut (27).
Connect plug (12) to bulkhead receptacle (13).
Install harness support strap (17) on bulkhead with
two screws (14), washers (16), and new Iockwashers
(15).
Connect plug (19) to STE/lCE resistor box (18).
Install 10 retaining straps (21) on 10 vehicle mounts
(20) with 10 screws (22), washers (24), and new
Iockwashers (23).
Install two groups of three ground leads (5) on two
vehicle mounts (3) with two screws (6) and four new
Iockwashers (4).
Install DCA receptacle (10) and dust cap (1) on
vehicle bracket (2) with four screws (11), washers (9),
new Iockwashers (8), and nuts (7).
Install dust cap (1) on DCA receptacle (10).
FOLLOW-ON MAINTENANCE:
l Connect battery ground cables (para 7-41).
l Install engine AFES brackets Nos. 1 and 2 (para 21-8).
l Close drivers hatch cover (refer to TM 9-2350-287-10).
l Move right projectile rack assembly into position
(refer to TM 9-2350-287-10).
7-228