TM 9-2350-287-20-17-16. HYDRAULIC CONTROL GAGE PANEL ASSEMBLY REPAIR (continued).b.1.2.3.4.5.6.7.8.7-46ASSEMBLYInstall toggle switch (24) and guard(25) on cover (8) with two newIockwashers (26) and two screws(27).Install indicator light (19) on cover (8)with two new Iockwashers (32) andtwo screws (33).Install bulb (29), new preformedpacking (30), and lens (31) onindicator light (19).Install oil level gage (18), temperaturegage (22), two lenses (28 and 34),and ground lead (5) on cover (8) withtwo mounting clamps (23), four newIockwashers (35), and four nuts (36).Connect electrical lead 27 (21) and electrical lead 664 (20) to rear of temperature gage (22).Connect electrical lead 40 (17) to rear of indicator light (19).Connect electrical lead 27 (16) and electrical lead CD (15) to rear of oil level gage (18).Connect electrical lead AAA(11), electrical lead 10(13), and electrical lead AAB (12) to rear of toggle switch(14).