TM 9-2350-287-20-1I2-19. TROUBLESHOOTING CHART (continued).o. PERSONNEL VENTILATION BLOWER (continued).(3) PERSONNEL VENTILATION BLOWER DOESNOT OPERATE IN EXHAUST MODE (continued).CONTINUED FROM AIs voltage indicated?IIIGO TO STEP FIB.WARNINGWhen AFES relay cover is removed,use caution while working aroundexposed electrical terminals toavoid electrical shock. Do not shortout terminals with tools or barehands.1. Remove AFES control relay cover by re-moving 4 screws, 4 washers, 4 Iockwashersand cover.2. On AFES relay #1 (middle) place redprobe of multimeter on pin 13 and black leadof multimeter to pin 2 (ground).3. Ensure PERSONNEL VENTILATORBLOWER switch is in the EXHAUST posi-tion.4. Turn MASTER switch ON (refer to TM 9-2350-287-10).5. Check for 24 ± 3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?IIRepair wire 159C-2 or replace harness12351461 (para 7-79). Verify problem issolved.C o n t i n u e d o n n e x t p a g e2-259