TM 9-2350-287-20-1I2-19. TROUBLESHOOTING CHART (continued).o. PERSONNEL VENTILATION BLOWER (continued).(2) PERSONNEL VENTILATION BLOWER DOESNOT OPERATE IN INTAKE MODE (continued).CONTINUED FROM DReplace personnel ventilator blower (para7-81 ). Verify problem is solved.E. 1. Install wiring harness 12351461 on PER-SONNEL VENTILATOR BOWLER motor.2. Remove wiring harness 12351461 con-nector from accessory control box (circuits159A, 1596, 159C).3. Place red lead of multimeter to pin A onaccessory control box plug, and black lead ofmultimeter to ground.4. Turn MASTER switch ON (refer to TM 9-2350-287-1O).5. Position PERSONNEL VENTILATORBLOWER switch to INTAKE position.6. Check for 24 ± 3 vdc.7. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage present?r1Replace personnel ventilator blower (para7-81 ). Verify problem is solved.Replace PERSONNEL VENTILATORBLOWER switch (para 7-9). Verify problemis solved.END OF TASK2-257
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business