2-19. TROUBLESHOOTING CHART (continued).o.PERSONNEL VENTILATION BLOWER (continued).(4) PERSONNEL VENTILATION BLOWER OPER-ATES, BUT DOES NOT COME ON AUTOMATI-CALLY IN EXHAUST MODE DURING AFESTEST (continued).CONTINUED FROM AA. 3. Turn MASTER switch ON (refer to TM 9-2350-287-10).4. Perform AFES crew fire detection test (re-fer to TM 9-2350-287-10).5. Watch multimeter after actuating MANUALDISCHARGE switch. A pulse voltage for aminimum duration of 0.5 seconds should beread.6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage present?Proceed to AFES system troubleshooting,fault (para 2-19. v (1) and 2-19. v (2)).B.WARNINGMake sure you do not touch leadsof multimeter to any terminals otherthan those specified in the followingprocedures.1. Remove AFES control relay cover by re-moving four screws, four washers, fourIockwashers and cover.DiscardIockwashers.2. Remove wiring harness 12351461 from#3 (top) AFES control relay.3. Place red lead of multimeter into socket Bof wiring harness 12351461 at #3 (top) relay.Place black lead of multimeter into socket Bof harness 12351461 at AFES wiring har-ness.4. Check for continuity.Continued on next page2-263TM 9-2350-287-20-1