TM 9-2350-287-20-1I2-19. TROUBLESHOOTING CHART (continued).o. PERSONNEL VENTILATION BLOWER (continued).(2) PERSONNEL VENTILATION BLOWER DOESNOT OPERATE IN INTAKE MODE (continued).CONTINUED FROM BC. 1. Install wiring harness 12351461 on per-sonnel ventilator blower motor.2. Disconnect harness 12351461 from ac-cessory control box (circuits 159A, 1596,159C).3. Place red probe of multimeter on pin A ofharness 12351461 and black lead of mutti-meter to pin 14 of AFES relay #2 (bottom).4. Check for continuity.Is continuity indicated in the INTAKE circuit?IRepair wire 159A or replace harness12351461 (para 7-79) Verify problem ISReplace AFES control relay #1 (bottom)(para 21-1 1). Verifyproblem is solved.CONTINUED FROM STEP AD. 1. Place red lead of multimeter on socket Cand black lead of multi meter to ground.2. Turn MASTER switch ON (refer to TM 9-2350-287-1O).3. Ensure PERSONNEL VENTILATORBLOWER switch is in INTAKE position.4. Check for 24 ± 3 vdc.5. Turn MASTER switch to OFF (refer to TM9-2350-287-10).Is voltage present?Continued on next page2-256solved.