TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).j.AUXILIARY OUTLET (continued).(1) AUXILIARY OUTLET FAILS TO OPERATE. All otherelectrical systems operate (continued).CONTINUED FROM BB.4. Turn MASTER switch ON (refer to TM 9-2350-287-1 0).5. Check for 24 +3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-1 O).Is voltage indicated?Replace auxiliary outlet (para7-9). Verify problem is solved.c.NOTEFor the following steps (C&D),the driver’s instrument panelneeds to be removed (refer toTM 9-2350-287-10).1. Reconnect lead 37 of harness 12330252to auxiliary outlet.2. Disconnect harness 12330252 lead 37/38from circuit breaker no. 1, panel no. 1.3. Place multimeter red Iead on circuit breakerno. 1 connector pin and ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-10).5. Check for 24 +3 vdc.6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage indicated?Continued on next page2-214