TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
i
AUXILIARY OUTLET (continued).
(1) AUXILIARY OUTLET FAILS TO OPERATE. All other
electrical systems operate (continued).
CONTINUED FROM C
Notify Direct Support maintenance.
D.
1. Reconnect wire 37-38 to circuit breaker
no. 1.
2. Disconnect wire 10A of harness 12376405
from circuit breaker no. 1 input.
3. Place red lead of multimeter in wire 10A
and ground black lead.
4. Turn MASTER switch ON (refer to TM 9-
2350-287-10).
5. Check for 24 + 3 vdc.
6. Turn MASTER switch OFF (refer to TM 9-
2350-287-10).
7. Check for 24 + 3 vdc.
Is voltage indicated?
Replace circuit breaker no. 1 (para 7-
11). Verify problem is solved.
Repair wire 10A or replace harness
12376405 (para 7-57). Verify problem is
solved.
END OF TASK
2-215