TM 9-2350-277-20-6
REPLACE VFM COUPLING (M981A3 ONLY) Continued
0910 00
INSTALLATION
1.
Install clamp (1) on coupling (2) and install coupling and clamp over adapter (3) on targeting station VFM heater (4).
Tighten clamp securely.
2.
Install clamp (5) on coupling (2) and install coupling and clamp over tee (6). Tighten clamp securely.
3.
Install clamp (7) on coupling (8) and install coupling and clamp over adapter (9) on communications station VFM heater
(10). Tighten clamp securely.
4.
Install clamp (11) on coupling (8) and install coupling and clamp over tee (6). Tighten clamp securely.
5.
Install clamp (12) on coupling (13) and install coupling and clamp on tee (6). Tighten clamp securely.
6.
Install clamp (14) on coupling (13) and install coupling and clamp over elbow (15). Tighten clamp securely.
7.
Install clamp (16) on coupling (17) and install coupling and clamp over elbow (15). Tighten clamp securely.
8.
Install clamp (18) on coupling (17) and install coupling and clamp over elbow (19). Tighten clamp securely.
9.
Install clamp (20) on coupling (21) and install coupling and clamp over elbow (19). Tighten clamp securely.
10. Install clamp (22) on coupling (21) and install coupling and clamp over elbow (23). Tighten clamp securely.
11. Install clamp (24) on coupling (25) and install coupling and clamp to elbow (23). Tighten clamp securely.
0910 00-5