TM 9-2350-277-20-6
REPLACE VFM COUPLING (M981A3 ONLY) Continued
0910 00
25. Loosen clamp (10). Remove clamp (10) and coupling (9) from elbow (11).
26. Loosen clamp (12). Remove clamp (12) and elbow (11) from coupling (13).
27. Loosen clamp (14). Remove clamp (14) and coupling (13) from tee (15).
28. Loosen clamp (16). Remove clamp (16) and tee (15) from coupling (17).
29. Loosen clamp (18). Remove clamp (18) and coupling (17) from adapter (19) on communications station VFM
heater (20).
30. Loosen clamp (21). Remove clamp (21) and tee (15) from coupling (22).
31. Loosen clamp (23). Remove clamp (23) and coupling (22) from adapter (24) on targeting station VFM heater (25).