TM 9-2350-277-20-6REPLACE M25/M25A1 VFM HEATER (M981A3 ONLY) — Continued 0911 00INSTALLATIONNOTEApply corrosion preventive compound to all threaded fasteners.1. For left side VFM heaters, install VFM heater (13), four washers (11), new lockwashers (10), and screws (9).2. For right side VFM heaters, install VFM heater (13), four washers (11), screws (9), and locknuts (12).3. Install hose assembly (7) and clamp (6) on adapter (8). Tighten clamp securely.4. Install hose assembly (4) and clamp (3) on adapter (5). Tighten clamp securely.5. Connect power lead (1) to heater jack (2).FOLLOW-THROUGH STEPS1. Connect battery ground leads (WP 0339 00).2. Check air flow of NBC System. Follow procedures in TM 3-6680-316-10.END OF TASK0911 00-2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business