REPLACE VFM COUPLING (M981A3 ONLY)
TM-9-2350-277-20-6 Carrier Personnel Full Tracked Armored M113A3 2350-01-219-7577 (EIC AE7) Carrier Command Post Light Tracked M577A3 2350-01-369-6085 (EIC AE7) Manual
Page Navigation
329
330
331
332
333
334
335
336
337
338
339
TM 9-2350-277-20-6
REPLACE PRECLEANER/PARTICULATE FILTER ASSEMBLY (M981A3 ONLY) —
Continued
0909 00
5.
Install ground lead (1) on M1A1-19 precleaner and particulate filter assembly (6). Secure with retained lockwasher (8)
and screw (9)
6.
Seal ground lead (1) and mating electrical surfaces with corrosion preventive compound.
7.
Install two clamps (10) and
couplings
(11) onto M1A1-19 precleaner and particulate filter assembly (6). Tighten clamps
securely.
8.
Connect lead (12) to receptacle (13).
FOLLOW-THROUGH STEPS
1.
Connect battery ground leads (WP 0339 00).
2.
Check air flow of NBC System. Follow procedures in TM 3-6680-316-10.
END OF TASK