TM 9-2350-277-20-5
REPLACE M3 NBC HOSES AND FITTINGS (M1059A3 ONLY) Continued
0788 00
8.
Loosen clamp (17) and remove operators inlet hose (12) from air purifier (18).
9.
Remove commanders station hose (1) from connector (2) and two clips (3) on top plate.
10. Remove two screws (4), lockwashers (5), and clips (3) from top plate. Discard lockwashers.
11. Cut straps (6) that secure leads (7) to commanders station hose (1). Discard straps.
12. Remove screw (8), lockwasher (9), and clamp (10) from bracket (11) and top plate. Remove clamp from commanders
station hose (1).
13. Remove screw (12), lockwasher (13), and clamp (14) from top plate. Remove clamp from commanders station hose (1).
Discard lockwashers.
14. Loosen clamp (15) and remove commanders station hose (1) from adapter (16) on heater (17).
15. If damaged, remove adapter (16) from heater (17).
16. Remove commanders station hose (1) and grommet (18) from mount (19).
17. Loosen clamp (20) and remove hose (21) from adapter (22) on heater (17).
18. If damaged, remove adapter (22) from heater (17).
0788 00-2