TM 9-2350-277-20-5REPAIR PERSONNEL HEATER CONTROL BOX — Continued 0702 00ASSEMBLYNOTEBefore connecting electrical leads, check tags and wiring diagram below to verify properconnection.NOTEMake sure key in receptacle is at the top.1. Install receptacle (13) in control box (14).a. Install receptacle (13) in control box (14). Secure with four new lockwashers (12) and screws (11).b. Install lead 17-D (9) on circuit breaker (10). Secure with lockwasher (8) and screw (7).c. Install lead 12-B (17) on HI-LO switch (18). Secure with lockwasher (16) and screw (15).d. Install lead 19-E (5), lead 20-C (4), and lead 14-A (3) on RUN-OFF-START switch (6). Secure with threelockwashers (2) and screws (1).0702 00-5