TM 9-2350-277-20-4
REPLACE POWER PLANT DOOR (ALL EXCEPT M113A3)
0471 00
THIS WORK PACKAGE COVERS:
Removal page 0471 00-1
Installation page 0471 00-2
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Socket Wrench Set (WP 0926 00, Item 72)
Torque Wrench (WP 0926 00, Item 81)
Sling (WP 0926 00, Item 47)
Suitable Lifting Device
Personnel Required
Unit Mechanic
Helper (H)
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Trim vane lowered and disconnected (see your -10)
Power plant door open (see your -10)
REMOVAL
WARNING
Power plant door is heavy. It can fall and injure you. Do not remove housing before relieving
spring tension by lifting and holding with lifting device.
Damaged lifting slings can fail with load. soldiers can be killed or injured. Inspect all slings
before use. Do not use damaged slings.
1.
Connect a suitable lifting device and sling around power plant door. Hold door straight up until tension is gone.
0471 00-1