TM 9-2350-277-20-4REPLACE POWER PLANT DOOR (ALL EXCEPT M113A3) 0471 00THIS WORK PACKAGE COVERS:Removal page 0471 00-1Installation page 0471 00-2INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Socket Wrench Set (WP 0926 00, Item 72)Torque Wrench (WP 0926 00, Item 81)Sling (WP 0926 00, Item 47)Suitable Lifting DevicePersonnel RequiredUnit MechanicHelper (H)ReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered and disconnected (see your -10)Power plant door open (see your -10)REMOVALWARNINGPower plant door is heavy. It can fall and injure you. Do not remove housing before relievingspring tension by lifting and holding with lifting device.Damaged lifting slings can fail with load. soldiers can be killed or injured. Inspect all slingsbefore use. Do not use damaged slings.1. Connect a suitable lifting device and sling around power plant door. Hold door straight up until tension is gone.0471 00-1