TM 9-2350-277-20-2
REPLACE GLOW PLUG CONTROLLER Continued
0210 00
INSTALLATION
1.
Install glow plug controller (1), two bolts (2), new lockwashers (3), nuts (4), and four washers (5) on mounting bracket
(6). TIGHTEN BOLTS TO 156-204 LB-IN (18-23 N m) TORQUE.
2.
Connect glow plug harness (7) to right side (8) of glow plug controller (1).
3.
Connect glow plug power harness (9) to left side (10) of glow plug controller (1).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).
2.
Install power plant access panel (see your -10).
END OF TASK
0210 00-3/4 blank