TM 9-2350-277-20-2REPLACE GLOW PLUG CONTROLLER — Continued 0210 00INSTALLATION1. Install glow plug controller (1), two bolts (2), new lockwashers (3), nuts (4), and four washers (5) on mounting bracket(6). TIGHTEN BOLTS TO 156-204 LB-IN (18-23 N m) TORQUE.2. Connect glow plug harness (7) to right side (8) of glow plug controller (1).3. Connect glow plug power harness (9) to left side (10) of glow plug controller (1).FOLLOW-THROUGH STEPS1. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).2. Install power plant access panel (see your -10).END OF TASK0210 00-3/4 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business