TM 9-2350-277-20-2REPLACE GLOW PLUG POWER HARNESS — Continued 0211 002. Connect glow plug power harness (1) on left side (4) of glow plug controller (5).3. Remove nut (6) from ground terminal (7). Install blue ground lead (8), new lockwasher (9), and nut on ground terminal.4. Remove nut (10) from switch terminal (11). Install orange switch lead (12), new lockwasher (13), and nut on switchterminal.5. Remove nut (14) from battery terminal (15). Install red double lead (16), new lockwasher (17), and nut on batteryterminal.FOLLOW-THROUGH STEPS1. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).2. Install power plant access panel (see your -10).3. Install driver’s power plant access panel (see your -10).END OF TASK0211 00-3/4 blank