K To check wire 82, open connector at engine disconnect bracket.
Place red multimeter lead in connector socket for wire 82 and
black lead to ground. Check for voltage. If no voltage, repair
or replace wire 82 from engine disconnect bracket to master
relay (Appx F). If voltage is present, go to step L.
L
Remove power plant from vehicle (p 3-1). Connect special equip-
ment for operation of power plant out of vehicle (P 3-25). Place
red multimeter lead on wire 14B at starter solenoid. Ground
black wire. Place shift lever in neutral, push STARTER switch,
and check for voltage at wire 14B. If no voltage, repair or
replace wire 14B from engine disconnect bracket to starter
solenoid (p 6-64). If voltage is present, go to step M.
TA310432
2-73
TM 9-2350-267-20