2-72Change 4TM 9-2350-267-20IWith starter relay connector still connected use jumper wire betweensocket C and socket B. If engine cranks, replace starter relay (p 6-5). Ifengine fails to crank, reconnect relay connector and go to step J.JTo check circuit 14B, open connector at engine disconnect bracket. Usingmultimeter, place red lead in socket P and black lead to ground. PushSTARTER switch and cheek for voltage. If no voltage, repair or replacewire 14B from engine disconnect bracket to starter relay (p 6-68). If voltageis present, reconnect wire 14B and go to Step K.