2-72
Change 4
TM 9-2350-267-20
I
With starter relay connector still connected use jumper wire between
socket C and socket B. If engine cranks, replace starter relay (p 6-5). If
engine fails to crank, reconnect relay connector and go to step J.
J
To check circuit 14B, open connector at engine disconnect bracket. Using
multimeter, place red lead in socket P and black lead to ground. Push
STARTER switch and cheek for voltage. If no voltage, repair or replace
wire 14B from engine disconnect bracket to starter relay (p 6-68). If voltage
is present, reconnect wire 14B and go to Step K.