2-68
TM 9-2350-267-20
NOTE
Turn Master switch ON, steps A through N.
A
Disconnect wire 10 from circuit breaker input. Place red lead
of multimeter in connector and black lead to ground. Check for
voltage. If voltage is present, go to step B. If no voltage, repair
or replace wire 10 of input circuit (p 6-77).
B
Disconnect wire 10 from circuit breaker output. Using
multimeter, place red lead in circuit breaker output and black
lead to ground. Check for voltage. If voltage is present, go to
step C. If no voltage, replace circuit breaker (p 6-54).
TA310427