TM 9-2350-267-10OPERATING THE APU - Continued9.10.11.12.Continue charging batteries until charge indicator in supported vehicle readswell into normal range.Turn APU GENerator switch (6) OFF, and turn APU FUEL SHUT OFF switch(7) OFF to shutdown APU.WARNINGTo avoid injury, turnMASTER switches inboth vehicles OFF be-fore disconnectingslave cable.Turn OFF MASTER switchin each vehicle.Disconnect and stow slavecable.Charging Dead Batteries with APUNOTEThis procedure applies only to vehicles with dead batter-ies. If any lights or gages function when a vehicle’s MAS-TER switch is ON, batteries are low, not dead. To chargelow batteries see page 2-123.1. Before trying to charge batteries, do the following:a. Check batteries for broken case, broken cables, severe corrosionand other damage. Notify Organizational Maintenance if batteriesare badly damaged.b. Check electrolyte level (TM 9-6140-200-14). Notify OrganizationalMaintenance if electrolyte is not at proper level.2-125