TM 9-2350-267-10OPERATING THE APU - ContinuedElectrical Support of Another VehicleUnder normal conditions, APU generator can supply enough electrical power to operate itsown electrical system and that of another vehicle (ie M109A2 or another M992) which pos-sesses a compatible electrical system. There are limitations to the generator’s output,however. When your vehicle’s hydraulic system operates under load, the generator mayoccasionally switch off. This is only a temporary situation, and the generator wili automati-cally switch on when hydraulic pressure decreases.1. Park your vehicle close enough to the supported vehicle so that the slave ca-bie can be interconnected at the slave receptacles of both vehicles. if yourM992 is to support a self-propelled howitzer during conveyor operation, posi-tion your vehicle back-to-back with the howitzer and depioy the conveyor (p2-148).2. With the brake pedal depressed,parking brake lock handle (2).place the shift iever (1) in N (neutral) and setWARNINGTo avoid personai injury and vehicle damage, turn OFFthe MASTER switch and all other electrical switches inboth vehicles.3. Shut down vehicle main engine(s). Turn MASTER switches OFF inboth vehicles.2-120