TM 9-2350-261-34
42.
43.
44.
45.
46.
Remove five screws (1) from weldnuts (2)
(M113A2).
Secure personnel heater fuel hose (3) to
eight weldnuts (2) with five screws, three
kit screws (1), and eight clamps (4)
(M113A2).
Remove one screw (1) from one weldnut (2)
(M741A1).
Secure personnel heater fuel hose (3) to
three weldnuts (2) with one screw, two kit
screws (1), and three clamps (4) (M741A1).
Secure personnel heater fuel hose (3) to
hydraulic tube (5) with strap (6) (M741A1).
goggles and
W A R N I NG
Dry
cleaning
solvent
P - D - 6 8 0 is
toxic
and
flammable. Always use in
an open area with good air
flow, away from sparks,
h e a t , o r f l a m e s . W e ar
gloves.
Do not breathe
vapors. Avoid contact with skin, eyes, and
clothes. If you get dizzy while using
solvent, breathe fresh air and get medical
help. If solvent gets on hands, wash them.
If solvent gets in eyes, flush eyes with
fresh water and get medical help
immediately.
Keep fire
extinguisher
nearby.
47.
48.
Clean external threads of fittings with dry
cleaning solvent.
Apply a thin, even coat of primer and then
sealing compound to cleaned external pipe
threads of fittings. Do not apply primer or
sealing compound beyond small end of
threads.
11-8