TM9-2350-261-34
N O T E
If pump has been replaced, follow steps 28
thru 3 0 .
28.
29.
30.
31.
32.
33.
Install new packing (1) and elbow (2) in
differential oil pump (3).
Install nut (4) on elbow (5).
Install new packing (6), retainer (7), and
elbow (5) in differential oil pump (3).
Install new packing (8) and quick disconnect
half (9) on elbow (5).
Connect differential oil hose (10) to
elbow (2).
Install turnbuckle (11) on idler arm bracket
(12). Secure with screw (13) and nut (14).
N O T E
When replacing generator drive belts, re-
place in matched sets only.
35.
36.
There can be different generator compo-
nents on transfer gearcase. Refer to
TM 9-2350-261-20 for 200 amp generator
maintenance components (M577A2 and
M1068 only).
34. Install two generator drive belts (15) on
generator pulley (16) and transfer gearcase
pulley (17).
N O T E
Check alignment of generator pulley with
transfer gearcase drive pulley. If neces-
sary, position generator bracket until
pulleys are alined within 1/8 inch (3 mm).
Turn tumbuckle (11) to the right until belt
deflection at midspan is 1/2 to 5/8 inch
(13 to 16 mm) when measured with
machinist rule.
Tighten locknut (18) on rod end (19).
I
3-22
Change 3