TM9-2350-261-34N O T EIf pump has been replaced, follow steps 28thru 3 0 .28.29.30.31.32.33.Install new packing (1) and elbow (2) indifferential oil pump (3).Install nut (4) on elbow (5).Install new packing (6), retainer (7), andelbow (5) in differential oil pump (3).Install new packing (8) and quick disconnecthalf (9) on elbow (5).Connect differential oil hose (10) toelbow (2).Install turnbuckle (11) on idler arm bracket(12). Secure with screw (13) and nut (14).N O T EWhen replacing generator drive belts, re-place in matched sets only.35.36.There can be different generator compo-nents on transfer gearcase. Refer toTM 9-2350-261-20 for 200 amp generatormaintenance components (M577A2 andM1068 only).34. Install two generator drive belts (15) ongenerator pulley (16) and transfer gearcasepulley (17).N O T ECheck alignment of generator pulley withtransfer gearcase drive pulley. If neces-sary, position generator bracket untilpulleys are alined within 1/8 inch (3 mm).Turn tumbuckle (11) to the right until beltdeflection at midspan is 1/2 to 5/8 inch(13 to 16 mm) when measured withmachinist rule.Tighten locknut (18) on rod end (19).I3-22Change 3