TM9-2350-261-349. Loosen locknut (1) on rod end (2).10. Turn turnbuckle (3) to the left to loosen twogenerator drive belts (4).N O T EThere can be different generator compo-nents on transfer gearcase. Refer toTM 9-2350-261-20 for 200 amp generatormaintenance components (M577A2 andM1068 only). -11. Remove two generator drive belts (4) fromgenerator pulley (5) and transfer gearcasepulley (6).3-20Change 312. Remove nut (7), screw (8), and turnbuckle(3) from idler arm bracket (9).N O T EIf pump is to be replaced, follow steps 13thru 16.13.14.15.16.17.Drain transfer gearcase (see your LO).Disconnect differential oil hose (10) fromelbow (11).Remove quick disconnect half (12) andpacking (13) from elbow (14). Discardpacking.Remove nut (15), elbow (14), retainer (16),and packing (17) from differential oil pump(18). Discard packing.Remove elbow (11) and packing (19) fromdifferential oil pump (18). Discard packing.