TM9-2350-261-34
1.
2.
Measure resistance between power supply PS2 (+)
OUTPUT terminal (1) and pin A2 (2) of relay K6 (3).
Does multimeter read 0 ohms?
1.
2.
3.
Remove cable W4, plug P1 (1), from Power Control
Enclosure jack J25 (2).
Measure resistance between power supply PS2 (-)
OUTPUT terminal (3) and jack J25 (2) outer sleeve.
Does multimeter read 0 ohms?
1. Install cable W4, plug P1 (1), on Power Control
Enclosure jack J25 (2).
2. Verify no faults found.
1. Replace lead 31C
(page 6-118).
2. Verify no faults found.
1. Replace lead 32E
(Date 6-118).
2. Install cable W4, plug P1 (1),
on Power Control Enclosure
jack J25 (2).
3. Verify no faults found.
Change 3