TM 9-2350-261-20-4
REPLACE SMOKE GENERATOR GLOW PLUG CABLE ASSEMBLIES
0714 00
(M1059 ONLY) -- Continued
INSTALLATION
NOTE
There are two exterior cables, access plates, and smoke generators, left and right. Cables are
installed on carrier the same way. Only one exterior cable, access plate, and smoke generator is
shown. Remove cables as required.
1.
Install interior cable (1), four screws (2), and new locknuts (3) to right access plate (4).
2.
Connect exterior cable (5) to preheat harness jack (6) on panel (7) of right smoke generator (8).
3.
Connect exterior cable (5) to interior cable (1) in right access plate (4).
4.
Install interior cable (1), four screws (2), and new locknuts (3) to left access plate (4).
5.
Connect exterior cable (5) to interior cable (1) in left access plate (4).
6.
Connect exterior cable (5) to preheat harness jack (6) on panel (7) of left smoke generator (8).