CLEAN, INSPECT, ANDW A R N I N GREPLACEDry cleaning solvent isflammable. Keep it awayfrom heat or open flame.Use in well ventilated area.Do not let it get on yourskin.8. Clean hose and fitting with dry cleaningsolvent.9. Check hose. Replace broken, twisted, orworn hose.10. Check fitting. Replace fitting that is crackedor has stripped threads.I N S T A L L11.12.13.14.15.16.Apply a thin, evento cleaned externalinstallation.Install valve (1) incoat of sealing compoundthreads of fittings beforeelbow (2).Install new preformed packing (3) onelbow (2).Install elbow (2) in transmission (4).Tighten jamnut (5) on elbow (2). Useadjustable wrench.Connect hose (6) to two elbows (2 and 7).Install two hoses (6 and 8) on bracket (9).Secure with clamp (10), screw (11), andnew locknut (12).17.18.19.TM 9-2350-261-20-2Install two hoses (6 and 8) on transmission(4). Secure with two clamps (13), screw(14), and new key washer (15).Check transmission oil level (see your -LO).Install air cleaner element and container(page 7-7).W A R N I NGCarbon monoxide is poison-ous and can kill you. Do notidle engine with bottomaccess cover and powerplant access panels offunless there is ADEQUATEVENTILATION.20. Start engine (see your -10). Check for leaks.FOLLOW-THROUGH STEPS 1. power plant installed (page 5-11).END OF TASK18-5