CLEAN, INSPECT, AND REPLACE
12.
13.
W A R N I N G
Dry cleaning solvent is
flammable. Keep it away
from heat or open flame.
Use in well ventilated area.
Do not let it get on your
skin.
Clean hose and fittings with dry cleaning
solvent.
Check hose. Replace broken, twisted, or
worn hose.
14. Check fittings. Replace fittings that are
cracked or have stripped threads.
INSTALL
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
TM 9-2350-261-20-2
Install two hoses (11 and 12) on bracket
(13). Secure with clamp (14), two screws,
(15), and new locknut (16).
Install two hoses (11 and 12) on transmis-
sion (4). Secure with two clamps (17), screw
(18), and new key washer (19).
Check transmission oil level (see your LO).
W A R N I N G
Carbon monoxide is poison-
ous and can kill you. Do not
idle engine with bottom
access cover and power
plant access panels off
unless there is ADEQUATE
VENTILATION.
27. Start engine (see your -10). Check for leaks.
Apply a thin even coat of sealing compound
to cleaned external threads of fittings before
installation.
Install new preformed packing (1) on elbow
(2). Tighten jamnut (3). Use adjustable
wrench.
Install elbow (2) in transmission (4).
Install bushing (5) in oil cooler (6). Use pipe
wrench.
Install tee (7) on bushing (5).
Install elbow (8) on tee (7).
Install transmission high oil temperature
switch (9) in tee (7).
Connect circuit 327 lead (10) to switch (9).
Connect hose (11) to two elbows (2 and 8).
FOLLOW-THROUGH STEPS
1. Power plant installed (page 5-11).
END OF TASK
18-3