TM 9-2350-261-20-1INSTALL11.12.13.14.15.16.17.18.Apply sealing compound to cleaned externalthreads of fittings.Install adapter (1) in secondary filterassembly (2).Install tee (3) in adapter (1).Install elbow (4) and generator field switch(5) in tee (3).Secure filter assembly (2) to bracket (6)With two screws (7) and nuts (8).Connect circuits 1A and 1B plug (9) to fieldswitch (5) .Connect fuel supply hose (10) to elbow (4).Connect fuel supply hose (11) to filterassembly (2).19. Close drain valve (12) and fill filter assem-bly (2) with fuel.20. Install bleed plug (13) in filter assembly (2).21. Connect quick disconnect coupling (14).6 - 1 2 6
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business