TM 9-2350-261-20-1
REPLACE FUEL SUPPLY HOSES, TUBES, AND FITTINGS
(M981 ONLY)
DESCRIPTION
This task covers:
Remove (page 6-39).
Install (page 6-41).
INITIAL SETUP
Tools
General Mechanics Tool Kit (Item 30, App D)
Materials/Parts
Sealing compound (Item 46, App C)
Wiping rag (Item 61, App C)
Lockwasher (6)
lockwasher (4)
Strap (4)
Personnel Required
Unit Mechanic
References
See your -10
TM 9-2350-266-20
Equipment Conditions
Engine stopped/shutdown (see your -10)
Ramp lowered (see your -10)
Battery ground lead disconnected (page 13-2)
Fuel tanks drained (page 6-28)
Cargo area floor plates removed
(See TM 9-2350-266-20)
Power plant rear access panel removed
(page 24-27)
REMOVE
1.
2.
3.
4.
5.
WARNING
Fuel flowing over a metal
. surface
causes
static
electricity. This will cause a
spark unless the surface is
grounded.
NOTE
Tag hoses before removal.
Use wiping rags to wipe any spilled fuel.
Disconnect quick disconnect
quick disconnect half (2) at
bulkhead.
Disconnect fuel supply hose
eIbow (4).
half (1) from
power plant rear
(3) from buldkhead
Remove quick disconnect half (2) from
elbow (5).
Disconnect tube assembly (6) from
elbows (4 and 5).
Remove nut (7) and bulkhead elbow (4) from
power plant rear bulkhead.
GO TO NEXT PAGE
6-39