TM 9-2350-261-20-1
8. Press and release TEST button.
9. Turn on component to be tested.
N O T E
If .9.9.9.9 appears on display, the test
current is greater than 1500 amps and
cannot be measured with STW/ICE-R.
If display reads a value with a minus sign,
current probe has been installed back-
wards. Repeat steps 1 thru 5. Be careful
not to reinstall current probe backwards.
10. Observe VTM reading.
a. If VTM reads between 250 and 425
amps, test passes.
b. If reading is erratic or cannot be
obtained, see TM9-4910-571-12&P.
11. Turn off component in step 9.
12. Return to troubleshooting.
END OF TASK
Change1 3-295(3-296blank