TM 9-2350-261-20-1 NO AC POWER FROM TENT INTERFACE PANEL A5 INITIAL SETUPTools:References:General Mechanic’s Tool Kit (Item 30, App D)See your -10Digital multimeter (Item 43, App D)TM 11-7010-256-12&PSee M1068 Wiring DiagramPersonnel Required:(FO-9 thru FO-11)Power-Generation Equipment Repairer 52D10Equipment Conditions:Helper (H)Engine stopped/shutdown (see your –10)Carrier blocked (see your –10)WARNINGHIGH VOLTAGE is used inequipment. DEATH ON CONTACT mayresult if personnel fail toobserve safety precautions.NEVER work on equipment unless atleast one other person familiar with theoperation and hazards of the equipmentis nearby. That person should also befamiliar with giving first aid. When anoperator helps a mechanic, that operatormust be warned about dangerous areas.SHUT OFF POWER supply to equipmentbefore beginning work. Make sure allexternal power is off/disconnected.BE CAREFUL not to contact high-voltageconnections when installing or operatingthis equipment.3-226.14Change 3the operation of this