TM 9-2350-261-20-1
1.
2.
3.
4.
Have helper depress DC TO INVERTERS button (1) on
Power Control Enclosure panel.
Measure voltage between terminal 1 (2) of circuit
breaker CB2 (3) and ground.
Repeat measurement between terminal 2 (4) and
ground.
Does multimeter read 22 volts DC or more for both
measurements?
1. Raise faceplate (1) and secure to Power Control Enclo-
sure with ten new lockwashers (2) and screws (3).
2. Verify no faults found.
1. Replace circuit breaker CB2
(page 40.1-33).
2. Verify no faults found.
3 - 2 2 6 . 9