TM 9-2350-261-20-1
1. Turn MASTER SWITCH to OFF.
2. Remove instrument panel for access (page 11-2).
3. Remove front main harness circuit 27F plug (1)
from instrument panel cable assembly circuit 27F
jack (2).
4. Measure resistance between front main harness
circuit 27F plug (1) and circuit 27G pin on circuit
327/27G plug.
5. Does multimeter read 0 ohms?
Y ES
1. Install front main harness circuit 327/27G plug on
TRANS OIL HI TEMP indicator jack.
2. Repair instrument panel cable assembly circuit 27F
(page 14-9).
3. Verify no faults.
1. Repair front main harness
circuit 27G/27F
I
(page 14-3).
2. Verify no faults found
3-157