TM 9-2350-261-20-1
1.
2.
3.
Remove DIFF OIL HI TEMP indicator cover lens
(1), gasket (2), bulb (3) and gasket (4) from
indicator assembly.
Measure voltage between indicator center contact
and ground.
Does multimeter read less than 17 volts?
1.
2.
3.
Remove front main harness circuit 328/27K plug
(1) from DIFF OIL HI TEMP indicator jack (2).
Measure voltage between circuit 27K pin and plug
on ground.
Does multimeter read less than 17 volts?
1. Do any of the other indicators on the warning light
panel operate normally?
I
1. Repair front main harness circuit 27K (page 14-3).
2. Verify no faults found.
3-162
1. Replace DIFF OIL HI
TEMP indicator assembly
(page 11-22).
2. Verify no faults found.
1. Repair instrument panel
harness circuit 27F
(page 14-3).
2. Verify no faults found.