TM 9-2350-247-20-3
REPLACE WINCH POWER TAKEOFF CONTROL (M548A1)
0414 00
THIS WORK PACKAGE COVERS:
Removal (page 0414 00-1).
Cleaning (page 0414 00-2).
Installation (page 0414 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0541 00, Item 57)
Socket Wrench Set (WP 0541 00, Item 63)
Torque Wrench (WP 0541 00, Item 67)
Materials/Parts
GAA grease (WP 0542 00, Item 14)
Grommet
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Left grille removed (WP 0390 00)
Center seat raised (see your -10)
Cab center floor plate removed (WP 0394 00)
Power plant rear access covers/door removed
(see your -10)
Battery negative lead disconnected (WP 0292 00)
REMOVAL
1.
Loosen setscrew (1) that secures outer control cable (2) to power takeoff actuating lever (3).
2.
Remove jam nut (4), nut (5), and bracket (6) that secure outer control cable (2) to screw (7). Pull control cable from
bracket.
3.
Remove screw (8), washer (9), and clamp (10) that secure outer control cable (2) to power plant compartment.
0414 00-1