TM 9-2350-287-20-17-63. AIR CLEANER BLOWER MOTOR RELAY LEAD ASSEMBLY (12353259)REPLACEMENT (continued).3.4.5.6.7.b.1.2.3.4.5.6.Remove two screws (8) and Iockwashers (9) securing bottom of two straps (10). Discard Iockwashers.Remove leads 415A and 4125B (1 and 6) from two straps (10).Disconnect connector (13) from air cleaner blower motor relay (14).Disconnect lead 415 (12) from wiring harness lead 415(11).Disconnect lead 415 (15) from circuit breaker no. 6 (16).INSTALLATIONConnect lead 415 (15) to circuit breaker no. 6 (16).Connect lead 415 (12) to wiring harness lead 415(11).Connect connector (13) to relay (14).Install leads 415A and 415B (1 and 6) behind two straps (10), and secure with two screws (8) and newIockwashers (9).Secure leads 415A and 415B (1 and 6) to driver’s bulkhead with two straps (2), new Iockwashers (3),screws (4).Connect leads 415A and 415B (1 and 6) to neutral safety switch leads 415A ad 415B and (5 and 7).FOLLOWING MAINTENANCE:l Install center periscope (refer TM 9-2350-287-10).Install driver’s instrument panel (para 7-9).7-195