TM 9-2350-287-20-1
7-60. DRIVERS BULKHEAD TO APU VOLTAGE REGULATOR CABLE (12330256)
REPLACEMENT (continued).
3.
4.
5.
6.
b.
1.
2.
3.
4.
5.
6.
Disconnect cable plug (11) from APU
voltage regulator (12).
Disconnect ground lead connector (14)
from harness 12330248 lead (13).
Remove screw (8), Iockwasher (9) and
cable ground lug (10) from APU voltage
regulator (12). Discard Iockwasher.
Remove harness
vehicle.
INSTALLATION
12330256 from
Position harness 12330256 in vehicle.
Install new lockwasher (9), screw (8),
and cable ground lug (10) to APU voltage
regulator (12).
Connect ground lead connector (14) to
harness 12330248 lead (13).
Connect cable plug (11 ) to APU voltage
regulator (12).
Install washer (5), new Iockwasher (6),
screw (7), and cable (1) to bulkhead with
two retaining straps (4).
Connect cable 62 (1) and plug (3) to
drivers bulkhead receptacle (2).
FOLLOW-ON MAINTENANCE:
l Connect battery ground cables (para 7-41).
7-190